summaryrefslogtreecommitdiffstats
path: root/collectors/charts.d.plugin/apcupsd/metadata.yaml
blob: d0521c3eca9a8051dee7f7c4d3dfde17ea2879b7 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
# yamllint disable rule:line-length
---
meta:
  plugin_name: charts.d.plugin
  module_name: apcupsd
  monitored_instance:
    name: APC UPS
    link: "https://www.apc.com"
    categories:
      - data-collection.ups
    icon_filename: "apc.svg"
  related_resources:
    integrations:
      list: []
  info_provided_to_referring_integrations:
    description: ""
  keywords:
    - ups
    - apc
    - power
    - supply
    - battery
  most_popular: false
overview:
  data_collection:
    metrics_description: "Monitor APC UPS performance with Netdata for optimal uninterruptible power supply operations. Enhance your power supply reliability with real-time APC UPS metrics."
    method_description: "The collector uses the `apcaccess` tool to contact the `apcupsd` daemon and get the APC UPS statistics."
  supported_platforms:
    include: []
    exclude: []
  multi_instance: false
  additional_permissions:
    description: ""
  default_behavior:
    auto_detection:
      description: "By default, with no configuration provided, the collector will try to contact 127.0.0.1:3551 with using the `apcaccess` utility."
    limits:
      description: ""
    performance_impact:
      description: ""
setup:
  prerequisites:
    list:
      - title: "Required software"
        description: "Make sure the `apcaccess` and `apcupsd` are installed and running."
  configuration:
    file:
      name: charts.d/apcupsd.conf
    options:
      description: |
        The config file is sourced by the charts.d plugin. It's a standard bash file.

        The following collapsed table contains all the options that can be configured for the apcupsd collector.
      folding:
        title: "Config options"
        enabled: true
      list:
        - name: apcupsd_sources
          description: This is an array of apcupsd sources. You can have multiple entries there. Please refer to the example below on how to set it.
          default_value: "127.0.0.1:3551"
          required: false
        - name: apcupsd_timeout
          description: How long to wait for apcupsd to respond.
          default_value: 3
          required: false
        - name: apcupsd_update_every
          description: The data collection frequency. If unset, will inherit the netdata update frequency.
          default_value: 1
          required: false
        - name: apcupsd_priority
          description: The charts priority on the dashboard.
          default_value: 90000
          required: false
        - name: apcupsd_retries
          description: The number of retries to do in case of failure before disabling the collector.
          default_value: 10
          required: false
    examples:
      folding:
        enabled: false
        title: "Config"
      list:
        - name: Multiple apcupsd sources
          description: Specify a multiple apcupsd sources along with a custom update interval
          config: |
            # add all your APC UPSes in this array - uncomment it too
            declare -A apcupsd_sources=(
                ["local"]="127.0.0.1:3551",
                ["remote"]="1.2.3.4:3551"
            )

            # how long to wait for apcupsd to respond
            #apcupsd_timeout=3

            # the data collection frequency
            # if unset, will inherit the netdata update frequency
            apcupsd_update_every=5

            # the charts priority on the dashboard
            #apcupsd_priority=90000

            # the number of retries to do in case of failure
            # before disabling the module
            #apcupsd_retries=10
troubleshooting:
  problems:
    list: []
alerts:
  - name: apcupsd_ups_charge
    link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf
    metric: apcupsd.charge
    info: average UPS charge over the last minute
    os: "*"
  - name: apcupsd_10min_ups_load
    link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf
    metric: apcupsd.load
    info: average UPS load over the last 10 minutes
    os: "*"
  - name: apcupsd_last_collected_secs
    link: https://github.com/netdata/netdata/blob/master/health/health.d/apcupsd.conf
    metric: apcupsd.load
    info: number of seconds since the last successful data collection
metrics:
  folding:
    title: Metrics
    enabled: false
  description: ""
  availability: []
  scopes:
    - name: ups
      description: "Metrics related to UPS. Each UPS provides its own set of the following metrics."
      labels: []
      metrics:
        - name: apcupsd.charge
          description: UPS Charge
          unit: "percentage"
          chart_type: area
          dimensions:
            - name: charge
        - name: apcupsd.battery.voltage
          description: UPS Battery Voltage
          unit: "Volts"
          chart_type: line
          dimensions:
            - name: voltage
            - name: nominal
        - name: apcupsd.input.voltage
          description: UPS Input Voltage
          unit: "Volts"
          chart_type: line
          dimensions:
            - name: voltage
            - name: min
            - name: max
        - name: apcupsd.output.voltage
          description: UPS Output Voltage
          unit: "Volts"
          chart_type: line
          dimensions:
            - name: absolute
            - name: nominal
        - name: apcupsd.input.frequency
          description: UPS Input Voltage
          unit: "Hz"
          chart_type: line
          dimensions:
            - name: frequency
        - name: apcupsd.load
          description: UPS Load
          unit: "percentage"
          chart_type: area
          dimensions:
            - name: load
        - name: apcupsd.load_usage
          description: UPS Load Usage
          unit: "Watts"
          chart_type: area
          dimensions:
            - name: load
        - name: apcupsd.temperature
          description: UPS Temperature
          unit: "Celsius"
          chart_type: line
          dimensions:
            - name: temp
        - name: apcupsd.time
          description: UPS Time Remaining
          unit: "Minutes"
          chart_type: area
          dimensions:
            - name: time
        - name: apcupsd.online
          description: UPS ONLINE flag
          unit: "boolean"
          chart_type: line
          dimensions:
            - name: online