parent195856feb38d27b4ac15fb5006615690a900a40b (diff)
Adjust alarm labels (#7600)
* adjust_alarm_labels: variable rename This commit renames the variables inside health * adjust_alarm_labels: Doc Changes documentation for the labels * adjust_alarm_labels: Fix typo this commit brings the fix for the documentation * adjust_alarm_labels: Table align Fix table align on documentation * adjust_alarm_labels: Table align Fix link * adjust_alarm_labels: Link * adjust_alarm_labels: Link * adjust_alarm_labels: Remove contradiction The previous documentation had a contradiction removed with this commit * adjust_alarm_labels: Missing conversion This commit brings the latest change to text
Diffstat (limited to 'health/REFERENCE.md')
-rw-r--r--health/REFERENCE.md19
1 files changed, 6 insertions, 13 deletions
diff --git a/health/REFERENCE.md b/health/REFERENCE.md
index 886942c869..5ddb65b485 100644
--- a/health/REFERENCE.md
+++ b/health/REFERENCE.md
@@ -68,7 +68,7 @@ Netdata parses the following lines. Beneath the table is an in-depth explanation
| [`delay`](#alarm-line-delay) | no | Optional hysteresis settings to prevent floods of notifications. |
| [`repeat`](#alarm-line-repeat) | no | The interval for sending notifications when an alarm is in WARNING or CRITICAL mode. |
| [`option`](#alarm-line-option) | no | Add an option to not clear alarms. |
-| [`label`](#alarm-line-label) | no | List of labels present on a host. |
+| [`host labels`](#alarm-line-host-labels) | no | List of labels present on a host. |
The `alarm` or `template` line must be the first line of any entity.
@@ -371,9 +371,9 @@ increasing. Eventually, the comparison will find the averages in the two time-fr
However, the issue was not resolved, it's just a matter of the newer data "polluting" the old. For such alarms, it's a
good idea to tell Netdata to not clear the notification, by using the `no-clear-notification` option.
-#### Alarm line `label`
+#### Alarm line `host labels`
-Defines the list of labels expected on a host. For example, let's suppose that `netdata.conf` is configured with the
+Defines the list of labels present on a host. For example, let's suppose that `netdata.conf` is configured with the
following labels:
```yaml
@@ -394,21 +394,14 @@ By defining labels inside of `netdata.conf`, you can now apply labels to alarms.
line to any alarms you'd like to apply to hosts that have the label `room = server`.
```yaml
-label: room = server
+host labels: room = server
```
-You can also combine labels when applying them to alarms. For example, if you want to raise a specific alarm only for hosts
-inside a room that were installed at a specific time, you can write the following label line:
-
-```yaml
-label: room = workstation AND installed = 201705
-```
-
-The `label` is a space-separated list that accepts simple patterns. For example, you can create an alarm
+The `host labels` is a space-separated list that accepts simple patterns. For example, you can create an alarm
that will be applied to all hosts installed in the last decade with the following line:
```yaml
-label: installed = 201*
+host labels: installed = 201*
```
See our [simple patterns docs](../libnetdata/simple_pattern/) for more examples.