From 5f25b41f7ec242fce43d0f745369c0ba9d25cb72 Mon Sep 17 00:00:00 2001 From: Sachin Kamat Date: Fri, 7 Mar 2014 07:44:00 +0000 Subject: iio: hid-sensor-magn-3d: Fix return values IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored the actual return values (which could be -EINVAL) and instead returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO upon success. Signed-off-by: Sachin Kamat Cc: Srinivas Pandruvada Signed-off-by: Jonathan Cameron --- drivers/iio/magnetometer/hid-sensor-magn-3d.c | 7 ++----- 1 file changed, 2 insertions(+), 5 deletions(-) diff --git a/drivers/iio/magnetometer/hid-sensor-magn-3d.c b/drivers/iio/magnetometer/hid-sensor-magn-3d.c index 41cf29e2a371..b2b0937d5133 100644 --- a/drivers/iio/magnetometer/hid-sensor-magn-3d.c +++ b/drivers/iio/magnetometer/hid-sensor-magn-3d.c @@ -110,7 +110,6 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev, struct magn_3d_state *magn_state = iio_priv(indio_dev); int report_id = -1; u32 address; - int ret; int ret_type; s32 poll_value; @@ -153,14 +152,12 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev, ret_type = IIO_VAL_INT; break; case IIO_CHAN_INFO_SAMP_FREQ: - ret = hid_sensor_read_samp_freq_value( + ret_type = hid_sensor_read_samp_freq_value( &magn_state->common_attributes, val, val2); - ret_type = IIO_VAL_INT_PLUS_MICRO; break; case IIO_CHAN_INFO_HYSTERESIS: - ret = hid_sensor_read_raw_hyst_value( + ret_type = hid_sensor_read_raw_hyst_value( &magn_state->common_attributes, val, val2); - ret_type = IIO_VAL_INT_PLUS_MICRO; break; default: ret_type = -EINVAL; -- cgit v1.2.3