summaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/netronome/nfp/flower/tunnel_conf.c
AgeCommit message (Collapse)Author
2019-01-16nfp: flower: enable MAC address sharing for offloadable devsJohn Hurley
A MAC address is not necessarily a unique identifier for a netdev. Drivers such as Linux bonds, for example, can apply the same MAC address to the upper layer device and all lower layer devices. NFP MAC offload for tunnel decap includes port verification for reprs but also supports the offload of non-repr MAC addresses by assigning 'global' indexes to these. This means that the FW will not verify the incoming port of a packet matching this destination MAC. Modify the MAC offload logic to assign global indexes based on MAC address instead of net device (as it currently does). Use this to allow multiple devices to share the same MAC. In other words, if a repr shares its MAC address with another device then give the offloaded MAC a global index rather than associate it with an ingress port. Track this so that changes can be reverted as MACs stop being shared. Implement this by removing the current list based assignment of global indexes and replacing it with an rhashtable that maps an offloaded MAC address to the number of devices sharing it, distributing global indexes based on this. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-01-16nfp: flower: ensure MAC cleanup on address changeJohn Hurley
It is possible to receive a MAC address change notification without the net device being down (e.g. when an OvS bridge is assigned the same MAC as a port added to it). This means that an offloaded MAC address may not be removed if its device gets a new address. Maintain a record of the offloaded MAC addresses for each repr and netdev assigned a MAC offload index. Use this to delete the (now expired) MAC if a change of address event occurs. Only handle change address events if the device is already up - if not then the netdev up event will handle it. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-01-16nfp: flower: ensure deletion of old offloaded MACsJohn Hurley
When a potential tunnel end point goes down then its MAC address should not be matchable on the NFP. Implement a delete message for offloaded MACs and call this on net device down. While at it, remove the actions on register and unregister netdev events. A MAC should only be offloaded if the device is up. Note that the netdev notifier will replay any notifications for UP devices on registration so NFP can still offload ports that exist before the driver is loaded. Similarly, devices need to go down before they can be unregistered so removal of offloaded MACs is only required on down events. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-01-16nfp: flower: remove list infastructure from MAC offloadJohn Hurley
Potential MAC destination addresses for tunnel end-points are offloaded to firmware. This was done by building a list of such MACs and writing to firmware as blocks of addresses. Simplify this code by removing the list format and sending a new message for each offloaded MAC. This is in preparation for delete MAC messages. There will be one delete flag per message so we cannot assume that this applies to all addresses in a list. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-01-16nfp: flower: ignore offload of VF and PF repr MAC addressesJohn Hurley
Currently MAC addresses of all repr netdevs, along with selected non-NFP controlled netdevs, are offloaded to FW as potential tunnel end-points. However, the addresses of VF and PF reprs are meaningless outside of internal communication and it is only those of physical port reprs required. Modify the MAC address offload selection code to ignore VF/PF repr devs. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-01-16nfp: flower: tidy tunnel related private dataJohn Hurley
Recent additions to the flower app private data have grouped the variables of a given feature into a struct and added that struct to the main private data struct. In keeping with this, move all tunnel related private data to their own struct. This has no affect on functionality but improves readability and maintenance of the code. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-11nfp: flower: increase scope of netdev checking functionsJohn Hurley
Both the actions and tunnel_conf files contain local functions that check the type of an input netdev. In preparation for re-use with tunnel offload via indirect blocks, move these to static inline functions in a header file. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-07nfp: flower: include geneve as supported offload tunnel typeJohn Hurley
Offload of geneve decap rules is supported in NFP. Include geneve in the check for supported types. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-07nfp: flower: use the common netdev notifierJakub Kicinski
Use driver's common notifier for LAG and tunnel configuration. Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Reviewed-by: John Hurley <john.hurley@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-07nfp: flower: remove unnecessary iteration over devicesJakub Kicinski
For flower tunnel offloads FW has to be informed about MAC addresses of tunnel devices. We use a netdev notifier to keep track of these addresses. Remove unnecessary loop over netdevices after notifier is registered. The intention of the loop was to catch devices which already existed on the system before nfp driver got loaded, but netdev notifier will replay NETDEV_REGISTER events. Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Reviewed-by: John Hurley <john.hurley@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-10-17net: Add netif_is_vxlan()Ido Schimmel
Add the ability to determine whether a netdev is a VxLAN netdev by calling the above mentioned function that checks the netdev's rtnl_link_ops. This will allow modules to identify netdev events involving a VxLAN netdev and act accordingly. For example, drivers capable of VxLAN offload will need to configure the underlying device when a VxLAN netdev is being enslaved to an offloaded bridge. Convert nfp to use the newly introduced helper. Signed-off-by: Ido Schimmel <idosch@mellanox.com> Reviewed-by: Petr Machata <petrm@mellanox.com> Acked-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-10-11nfp: replace long license headers with SPDXJakub Kicinski
Replace the repeated license text with SDPX identifiers. While at it bump the Copyright dates for files we touched this year. Signed-off-by: Edwin Peer <edwin.peer@netronome.com> Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: Nic Viljoen <nick.viljoen@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-07-22nfp: flower: ensure dead neighbour entries are not offloadedJohn Hurley
Previously only the neighbour state was checked to decide if an offloaded entry should be removed. However, there can be situations when the entry is dead but still marked as valid. This can lead to dead entries not being removed from fw tables or even incorrect data being added. Check the entry dead bit before deciding if it should be added to or removed from fw neighbour tables. Fixes: 8e6a9046b66a ("nfp: flower vxlan neighbour offload") Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-12nfp: flower: free dst_entry in route tablePieter Jansen van Vuuren
We need to release the refcnt on dst_entry in the route table, otherwise we will leak the route. Fixes: 8e6a9046b66a ("nfp: flower vxlan neighbour offload") Signed-off-by: Pieter Jansen van Vuuren <pieter.jansenvanvuuren@netronome.com> Signed-off-by: Louis Peens <louis.peens@netronome.com> Reviewed-by: Jakub Kicinski <jakub.kicinski@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-02-06nfp: fix kdoc warnings on nested structuresJakub Kicinski
Commit 84ce5b987783 ("scripts: kernel-doc: improve nested logic to handle multiple identifiers") improved the handling of nested structure definitions in scripts/kernel-doc, and changed the expected format of documentation. This causes new warnings to appear on W=1 builds. Only comment changes. Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-11-02nfp: flower: vxlan - ensure no sleep in atomic contextJohn Hurley
Functions called by the netevent notifier must be in atomic context. Change the mutex to spinlock and ensure mem allocations are done with the atomic flag. Also, remove unnecessary locking after notifiers are unregistered. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-09-26nfp: flower vxlan neighbour keep-aliveJohn Hurley
Periodically receive messages containing the destination IPs of tunnels that have recently forwarded traffic. Update the neighbour entries 'used' value for these IPs next hop. This prevents the neighbour entry from expiring on timeout but rather signals an ARP to verify the connection. From an NFP perspective, packets will not fall back mid-flow unless the link is verified to be down. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-09-26nfp: flower vxlan neighbour offloadJohn Hurley
Receive a request when the NFP does not know the next hop for a packet that is to be encapsulated in a VXLAN tunnel. Do a route lookup, determine the next hop entry and update neighbour table on NFP. Monitor the kernel neighbour table for link changes and update NFP with relevant information. Overwrite routes with zero values on the NFP when they expire. Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-09-26nfp: offload vxlan IPv4 endpoints of flower rulesJohn Hurley
Maintain a list of IPv4 addresses used as the tunnel destination IP match fields in currently active flower rules. Offload the entire list of NFP_FL_IPV4_ADDRS_MAX (even if some are unused) when new IPs are added or removed. The NFP should only be aware of tunnel end points that are currently used by rules on the device Signed-off-by: John Hurley <john.hurley@netronome.com> Reviewed-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-09-26nfp: offload flower vxlan endpoint MAC addressesJohn Hurley
Generate a list of MAC addresses of netdevs that could be used as VXLAN tunnel end points. Give offloaded MACs an index for storage on the NFP in the ranges: 0x100-0x1ff physical port representors 0x200-0x2ff VF port representors 0x300-0x3ff other offloads (e.g. vxlan netdevs, ovs bridges) Assign phys and vf indexes based on unique 8 bit values in the port num. Maintain list of other netdevs to ensure same netdev is not offloaded twice and each gets a unique ID without exhausting the entries. Because the IDs are unique but constant for a netdev, any changes are implemented by overwriting the index on NFP. Signed-off-by: John Hurley <john.hurley@netronome.com> Signed-off-by: Simon Horman <simon.horman@netronome.com> Signed-off-by: David S. Miller <davem@davemloft.net>